Power System Analysis
Project Design Services

Engineering Design

Power System Analysis

Whether an electrical installation runs safely and efficiently can only be proven with numerical analysis. Short-circuit calculations, load flow analyses, harmonic measurements, and protection coordination underpin every critical decision from equipment selection to operational safety. The power systems analysis service reveals the facility's electrical behaviour through engineering calculations and makes the risks visible.

Miratek performs analysis work with internationally accepted methods: IEC 60909 is the basis for short-circuit calculations and IEEE 519 for harmonic assessments. Analyses are modelled in power system software such as ETAP, and the results are presented not merely as a report but together with actionable improvement recommendations.

This service is used both at the design stage of new investments and for assessing the current state of operating facilities. Chronic problems such as selectivity issues, harmonic-driven heating, and inadequate reactive power compensation are resolved permanently on the strength of the analysis results.

Analysis Scope Summary

Analysis TypesShort circuit, load flow, harmonic, selectivity, and arc flash analysis
Reference StandardsIEC 60909 (short circuit), IEEE 519 (harmonics)
Modelling EnvironmentETAP and comparable power system analysis software
Application AreasIndustrial facilities, power plants, MV and LV distribution systems
DeliverablesAnalysis report, coordination curves, relay setting table, improvement recommendations
Field WorkPower quality and harmonic measurements with data collection

How We Work

1

Data Collection and Site Survey

Single-line diagrams, equipment nameplate data, and — where needed — field measurements provide the data for an up-to-date electrical model of the facility.

2

System Modelling

The facility is modelled in power system analysis software with transformer, cable, busbar, and load details.

3

Running the Analyses

Short-circuit, load flow, harmonic, and selectivity analyses are run scenario by scenario.

4

Evaluation and Reporting

Results are compared against the standard limit values; risks and non-conformities are prioritized and reported.

5

Improvement and Implementation

Corrective works such as relay settings, filter, or compensation revisions are designed and, on request, implemented.

Scope of Work

  • IEC 60909-based short-circuit calculations
  • Load flow and voltage drop analyses
  • Harmonic measurement and IEEE 519 compliance assessment
  • Protection coordination (selectivity) study and relay settings
  • Arc flash risk analysis
  • Reactive power compensation system assessment
  • Analysis report and improvement roadmap

Frequently Asked Questions

Why is harmonic analysis needed?

Drives, UPS units, and power electronic loads create harmonic distortion in the network, which leads to transformer and cable heating, compensation failures, and faults in sensitive devices. Harmonic analysis pinpoints the source and level of the distortion; a filter or system revision is then designed on that data.

What does a selectivity (protection coordination) study deliver?

In poorly coordinated protection schemes, a minor fault can black out the entire facility. The selectivity study sets the relay and breaker settings so that a fault disconnects only the affected zone. The result is minimal downtime and fast intervention when a fault occurs.

Can analysis be performed at an existing, operating facility?

Yes — a substantial part of the analysis is carried out without stopping the operation. Power quality measurements are taken while the facility runs; the modelling work is done from existing drawings and nameplate data. Checks that require field verification are aligned with planned maintenance shutdowns.