Data Center Electrical Infrastructures
Contracting Services

Physical Implementation

Data Center Electrical Infrastructures

In a data center, the electrical infrastructure is a critical layer that directly determines business continuity. Even a one-second interruption can lead to data loss, service downtime, and serious reputational damage. Data center electrical infrastructures are therefore designed and built with redundant power architectures, uninterruptible power supplies, and automatic transfer scenarios that leave no single point of failure.

Miratek acts as the single point of contact for data center and system room projects, running needs analysis, design, equipment procurement, site installation, and commissioning end to end. All disciplines — from UPS systems to generator integration, from busbar distribution to grounding — are coordinated under a single project plan.

Before commissioning, load bank tests and scenario-based outage drills verify that the system behaves as expected under real load. Handover is made together with test reports and as-built documentation.

Technical Scope Summary

Redundancy architecturesN+1, 2N, and 2N+1 topologies
Uninterruptible powerStatic UPS systems and battery banks
Emergency supplyGenerator systems with automatic transfer (ATS) integration
Distribution equipmentIEC 61439-compliant LV panels, busbar systems, in-rack power distribution (PDU)
Application areasEnterprise data centers, system rooms, server rooms, disaster recovery centers
Test scopeLoad bank tests, transfer scenarios, thermal inspections
Delivery modelTurnkey: design, procurement, installation, testing, and commissioning

How We Work

1

Site survey and needs analysis

The current and projected IT load, criticality level, and growth plan are evaluated to set the redundancy target.

2

Design

The single-line diagram, load distribution, UPS and generator sizing, and panel designs are prepared.

3

Equipment procurement

UPS, generator, panel, and busbar systems are procured against approved technical specifications, and factory acceptance tests are followed up.

4

Site installation

Cabling, panel installation, busbar works, and grounding are planned and executed to minimize operational downtime.

5

Testing and commissioning

Real-load simulation is performed with a load bank, and outage and transfer scenarios are verified one by one.

6

Maintenance and operations support

A periodic maintenance plan, thermal camera inspections, and battery health monitoring safeguard the continuity of the infrastructure.

Scope of Work

  • Installation of UPS systems and battery banks
  • Integration of generator and automatic transfer (ATS) systems
  • LV distribution panels, busbar, and rack feed infrastructure
  • Grounding and lightning protection systems
  • Critical load cabling and cable containment systems
  • Commissioning of energy monitoring and alarm systems
  • Load bank tests and commissioning documentation

Frequently Asked Questions

Should we choose an N+1 or a 2N architecture for our data center?

The decision depends on the criticality of the load carried and the acceptable downtime risk. An N+1 architecture tolerates a single component failure, while a 2N architecture provides two fully independent supply paths and maintains full redundancy even during maintenance. At the survey stage, we run a load analysis and evaluate the cost-risk balance of both options together with you.

Can the electrical infrastructure be renewed while our existing system room is live?

Yes — such works are carried out with a staged migration plan. The new infrastructure is built alongside the existing system, loads are transferred step by step during planned maintenance windows, and a rollback scenario is kept ready at every step. This keeps operational downtime to a minimum.

Which tests are performed before commissioning?

The system is run under real load with a load bank; UPS transfer times, generator start scenarios, and grid outage drills are verified one by one. All results are documented in test reports and added to the handover file.